C stud profile
The lipped C section is the main member of light steel frame (LGS) construction. It is used as the vertical stud in walls, as the joist in floors and ceilings, and as the rafter or chord in light roof trusses, normally seated in U track at the top and bottom.
Six web heights are listed (75–200 mm), with a 41 mm flange for the 75 and 89 mm webs and a 50 mm flange for the larger ones, and a 10 mm or 15 mm lip. Thickness t runs from 0.75–2.00 mm. Each piece is cut to the length on your request list.
The light gauge steel hangar kits of Pesina Steel are made of galvanised cold-formed profiles, with lattice trusses and double C columns.
Section drawn to scale from the listed dimensions; wall thickness shown thicker than scale for legibility.
Sizes, thicknesses and unit weights
| Size | mm | kg/m | ||||||
|---|---|---|---|---|---|---|---|---|
| h | b | c | t 0.75 | t 0.95 | t 1.15 | t 1.50 | t 2.00 | |
| C 75×41×10 | 75 | 41 | 10 | |||||
| C 89×41×10 | 89 | 41 | 10 | |||||
| C 100×50×15 | 100 | 50 | 15 | |||||
| C 140×50×15 | 140 | 50 | 15 | |||||
| C 150×50×15 | 150 | 50 | 15 | |||||
| C 200×50×15 | 200 | 50 | 15 | |||||
Click a thickness in the kg/m table to choose a length and quantity and add the line to your request list.
Section properties Ix / Iy (cm⁴), by thickness t (mm)
| Size | Ix / Iy (cm⁴) | ||||
|---|---|---|---|---|---|
| t 0.75 | t 0.95 | t 1.15 | t 1.50 | t 2.00 | |
| C 75×41×10 | 3.13 / 12.40 | 3.90 / 15.54 | 4.65 / 18.62 | 5.89 / 23.85 | 7.54 / 30.98 |
| C 89×41×10 | 3.31 / 18.29 | 4.13 / 22.96 | 4.92 / 27.53 | 6.24 / 35.33 | 7.99 / 46.00 |
| C 100×50×15 | 6.36 / 28.27 | 7.95 / 35.53 | 9.51 / 42.67 | 12.13 / 54.90 | 15.67 / 71.76 |
| C 140×50×15 | 7.10 / 61.25 | 8.88 / 77.08 | 10.61 / 92.71 | 13.54 / 119.56 | 17.50 / 156.84 |
| C 150×50×15 | 7.25 / 71.90 | 9.07 / 90.51 | 10.84 / 108.89 | 13.83 / 140.49 | 17.87 / 184.41 |
| C 200×50×15 | 7.87 / 141.50 | 9.84 / 178.29 | 11.77 / 214.69 | 15.01 / 277.45 | 19.40 / 365.05 |
Gross section properties calculated from nominal centreline dimensions; corner radii and stiffening ribs ignored. Not for structural design — effective properties to EN 1993-1-3 on request. Ix = about the axis parallel to the web, Iy = about the axis of symmetry.
Nominal weight, kg/m, by thickness t (mm). Nominal weights, calculated from the section geometry (steel density 7.85 kg/dm³); coating mass not added. Dimensions in mm. h = web height, b = flange, c = lip, a = top width or leg, w = wing or strap width, t = thickness.
Scroll the table sideways on narrow screens.
The weight formulas and the standards behind these tables are set out in the technical data.
Typical uses
- Vertical studs in load-bearing and partition wall frames.
- Floor joists and ceiling joists.
- Rafters, chords and web members of light roof trusses.
- Members of wall and roof panels framed before shipping.
Steel and coating
DX51D+Z, EN 10346. Cut to length: 1.0–11.9 m.
On request: structural grades S280GD+Z / S320GD+Z / S350GD+Z and a Z275 coating, subject to a minimum order, typically from 20 t.
Questions and answers
Which sizes and thicknesses of C stud profile are listed?
Sizes: C 75×41×10, C 89×41×10, C 100×50×15, C 140×50×15, C 150×50×15, C 200×50×15 (dimensions in mm). Thickness t: 0.75, 0.95, 1.15, 1.50, 2.00 mm. Choose a size and a thickness in the request form; the weight table on this page covers every combination.
What steel is used, and are other grades available?
DX51D+Z zinc-coated steel to EN 10346. On request: structural grades S280GD+Z / S320GD+Z / S350GD+Z and a Z275 coating, subject to a minimum order, typically from 20 t. State your choice in the note field of the request list.
What lengths can be requested?
Any length from 1.0 to 11.9 m, cut to length. The 11.9 m upper limit keeps the piece within the internal length of a 40 ft high-cube container, which is about 12 m.
How is the weight in the table calculated?
Weight in kg/m = developed centre-line length of the section (mm) × thickness t (mm) × 7.85 × 10⁻³. Example: C 89×41×10, t 1.15 mm gives about 1.68 kg/m. Values are nominal and exclude the coating.
Which U track goes with which C stud?
The U track page lists the same six web heights as the C studs, so a track and a stud of the same web height can be requested together on one list.
Used with
-
U track profile
Plain U section: top and bottom track in which the C studs are seated.
- Sizes
- h 75–200 · b 40 mm
- Thickness t
- 0.75–1.50 mm