Flat strap bracing
Flat strap is a galvanised steel band without a formed section. Fixed diagonally across a wall or roof frame it works as tension bracing; fixed across C studs it ties the frame together.
Four widths are listed: 30, 50, 75 and 100 mm. Thickness t runs from 0.95–1.50 mm. Strap can be requested cut to length, up to 11.9 m, or as rolls; mention rolls in the note field of the request list.
Section drawn to scale from the listed dimensions; wall thickness shown thicker than scale for legibility.
Sizes, thicknesses and unit weights
| Size | mm | kg/m | ||
|---|---|---|---|---|
| w | t 0.95 | t 1.15 | t 1.50 | |
| Strap 30 | 30 | |||
| Strap 50 | 50 | |||
| Strap 75 | 75 | |||
| Strap 100 | 100 | |||
Click a thickness in the kg/m table to choose a length and quantity and add the line to your request list.
Nominal weight, kg/m, by thickness t (mm). Nominal weights, calculated from the section geometry (steel density 7.85 kg/dm³); coating mass not added. Dimensions in mm. h = web height, b = flange, c = lip, a = top width or leg, w = wing or strap width, t = thickness.
Scroll the table sideways on narrow screens.
The weight formulas and the standards behind these tables are set out in the technical data.
Typical uses
- X-bracing and diagonal bracing in wall panels.
- Diagonal bracing in roof planes.
- Ties and strapping across studs.
Steel and coating
DX51D+Z, EN 10346. Cut to length: 1.0–11.9 m.
On request: structural grades S280GD+Z / S320GD+Z / S350GD+Z and a Z275 coating, subject to a minimum order, typically from 20 t.
Questions and answers
Which sizes and thicknesses of flat strap are listed?
Sizes: Strap 30, Strap 50, Strap 75, Strap 100 (dimensions in mm). Thickness t: 0.95, 1.15, 1.50 mm. Choose a size and a thickness in the request form; the weight table on this page covers every combination.
What steel is used, and are other grades available?
DX51D+Z zinc-coated steel to EN 10346. On request: structural grades S280GD+Z / S320GD+Z / S350GD+Z and a Z275 coating, subject to a minimum order, typically from 20 t. State your choice in the note field of the request list.
What lengths can be requested?
Any length from 1.0 to 11.9 m, cut to length. The 11.9 m upper limit keeps the piece within the internal length of a 40 ft high-cube container, which is about 12 m.
How is the weight in the table calculated?
Weight in kg/m = developed centre-line length of the section (mm) × thickness t (mm) × 7.85 × 10⁻³. Example: Strap 50, t 1.15 mm gives about 0.45 kg/m. Values are nominal and exclude the coating.
Is strap weight calculated differently?
The section is a plain rectangle, so the developed length is simply the strap width: weight in kg/m = width (mm) × t (mm) × 7.85 × 10⁻³.
Used with
-
C stud profile
Lipped C section: the stud, joist and rafter member of light steel frames.
- Sizes
- h 75–200 · b 41–50 · c 10–15 mm
- Thickness t
- 0.75–2.00 mm
The studs across which strap is fixed to tie the frame together.