U track profile
U track is the plain channel that carries the studs. It is fixed along the floor or slab as bottom track and along the ceiling or roof line as top track, and the C studs are seated between its flanges.
The listed web heights, 75–200 mm, are the same as for the C studs. The flange is 40 mm for every size, and thickness t runs from 0.75–1.50 mm. Track is cut to the length on your request list, up to 11.9 m.
Section drawn to scale from the listed dimensions; wall thickness shown thicker than scale for legibility.
Sizes, thicknesses and unit weights
| Size | mm | kg/m | ||||
|---|---|---|---|---|---|---|
| h | b | t 0.75 | t 0.95 | t 1.15 | t 1.50 | |
| U 75×40 | 75 | 40 | ||||
| U 89×40 | 89 | 40 | ||||
| U 100×40 | 100 | 40 | ||||
| U 140×40 | 140 | 40 | ||||
| U 150×40 | 150 | 40 | ||||
| U 200×40 | 200 | 40 | ||||
Click a thickness in the kg/m table to choose a length and quantity and add the line to your request list.
Section properties Ix / Iy (cm⁴), by thickness t (mm)
| Size | Ix / Iy (cm⁴) | |||
|---|---|---|---|---|
| t 0.75 | t 0.95 | t 1.15 | t 1.50 | |
| U 75×40 | 1.91 / 10.75 | 2.40 / 13.51 | 2.88 / 16.22 | 3.71 / 20.87 |
| U 89×40 | 2.01 / 15.87 | 2.52 / 19.96 | 3.03 / 23.99 | 3.90 / 30.91 |
| U 100×40 | 2.08 / 20.75 | 2.61 / 26.11 | 3.14 / 31.41 | 4.04 / 40.51 |
| U 140×40 | 2.27 / 45.69 | 2.85 / 57.58 | 3.42 / 69.36 | 4.41 / 89.68 |
| U 150×40 | 2.30 / 53.88 | 2.90 / 67.92 | 3.48 / 81.83 | 4.48 / 105.85 |
| U 200×40 | 2.45 / 108.43 | 3.08 / 136.82 | 3.70 / 164.99 | 4.77 / 213.76 |
Gross section properties calculated from nominal centreline dimensions; corner radii and stiffening ribs ignored. Not for structural design — effective properties to EN 1993-1-3 on request. Ix = about the axis parallel to the web, Iy = about the axis of symmetry.
Nominal weight, kg/m, by thickness t (mm). Nominal weights, calculated from the section geometry (steel density 7.85 kg/dm³); coating mass not added. Dimensions in mm. h = web height, b = flange, c = lip, a = top width or leg, w = wing or strap width, t = thickness.
Scroll the table sideways on narrow screens.
The weight formulas and the standards behind these tables are set out in the technical data.
Typical uses
- Top and bottom track of wall panels.
- Head and sill track at door and window openings.
- Rim or edge track at floor and roof panel ends.
Steel and coating
DX51D+Z, EN 10346. Cut to length: 1.0–11.9 m.
On request: structural grades S280GD+Z / S320GD+Z / S350GD+Z and a Z275 coating, subject to a minimum order, typically from 20 t.
Questions and answers
Which sizes and thicknesses of U track are listed?
Sizes: U 75×40, U 89×40, U 100×40, U 140×40, U 150×40, U 200×40 (dimensions in mm). Thickness t: 0.75, 0.95, 1.15, 1.50 mm. Choose a size and a thickness in the request form; the weight table on this page covers every combination.
What steel is used, and are other grades available?
DX51D+Z zinc-coated steel to EN 10346. On request: structural grades S280GD+Z / S320GD+Z / S350GD+Z and a Z275 coating, subject to a minimum order, typically from 20 t. State your choice in the note field of the request list.
What lengths can be requested?
Any length from 1.0 to 11.9 m, cut to length. The 11.9 m upper limit keeps the piece within the internal length of a 40 ft high-cube container, which is about 12 m.
How is the weight in the table calculated?
Weight in kg/m = developed centre-line length of the section (mm) × thickness t (mm) × 7.85 × 10⁻³. Example: U 89×40, t 1.15 mm gives about 1.50 kg/m. Values are nominal and exclude the coating.
Can U track be requested together with C studs?
Yes. Add both to the same request list. Use the same web height for the track as for the stud it should carry.
Used with
-
C stud profile
Lipped C section: the stud, joist and rafter member of light steel frames.
- Sizes
- h 75–200 · b 41–50 · c 10–15 mm
- Thickness t
- 0.75–2.00 mm
The studs that sit between the flanges of the track.