Technical data

The first sections apply to the five light steel (LGS) profile families. Drywall and ceiling profiles have their own section further down. Anything different from the standard (grade, a size that is not listed) goes in the note field of the request list.

Steel grades, light steel profiles

The five families are shown, with drawings and size tables, under light steel profiles.

GradeSupply
DX51D+ZStandard
S280GD+Z / S320GD+Z / S350GD+ZOn request, subject to a minimum order (typically from 20 t)

All grades are hot-dip zinc-coated flat steel to EN 10346.

Zinc coating, light steel profiles

ClassCoatingMass, both faces togetherSupply
Z275Zinc275 g/m²On request, subject to a minimum order (typically from 20 t)

Tolerances

Dimensional and cross-section tolerances are applied according to EN 10162 (cold rolled steel sections: technical delivery conditions, dimensional and cross-sectional tolerances). Weights on this site are nominal values from the section geometry, not measured values.

How unit weights are calculated, light steel profiles

Weight in kg/m = developed centre-line length L (mm) × thickness t (mm) × 7.85 × 10⁻³. The coating mass is not added. The developed length for each family is:

C studL = (h − t) + 2 (b − t) + 2 (c − t/2)
U trackL = (h − t) + 2 (b − t/2)
OmegaL = a + 2 (h − t) + 2 (w − t/2), approximate
L angleL = 2 (a − t/2)
Flat strapL = w

h web height, b flange, c lip, a top width (omega) or leg (L), w wing (omega) or strap width, all in mm.

Cut length and container fit, light steel profiles

Profiles are cut to the length on your list, from 1.0 to 11.9 m. The upper limit of 11.9 m is set by the internal length of a 40 ft high-cube container, about 12 m, so that the longest pieces can be loaded into the container.

Your request list adds up the approximate weight of your lines and shows a load estimate in containers or trucks.

Packaging

Profiles are bundled, strapped and labelled.

Drywall and ceiling profiles

Drawings, size tables and bundle weights for these four families are under drywall and ceiling profiles.

Made to TS EN 14195. Steel DX51D (EN 10346); zinc coating options Z100, Z140, Z275. Reaction to fire class A1. Yield strength at least 140 N/mm². Standard length 3000 mm; special lengths from 2000 to 8000 mm on special order. Sizes are written web × flange (× lip), in mm; the thickness range depends on the size.

ProfileSizes (mm)Thickness t (mm)Pcs per bundle
Ceiling C profile (CD 60/27)CD 60×27×6 (CD 60/27)0.40, 0.45, 0.50, 0.6012
Ceiling U profile (UD 28)UD 28×220.35, 0.40, 0.45, 0.50, 0.6024
Ceiling U profile (UD 28)UD 28×240.40, 0.45, 0.50, 0.6024
Ceiling U profile (UD 28)UD 28×270.45, 0.50, 0.6024
Wall C stud (drywall)CW 49×35×6 (CW 50)0.40, 0.45, 0.50, 0.6012
Wall C stud (drywall)CW 49×42×6 (CW 50)0.45, 0.50, 0.6012
Wall C stud (drywall)CW 49×47×6 (CW 50)0.45, 0.50, 0.60, 0.80, 0.90, 1.00⁦8–12⁩
Wall C stud (drywall)CW 74×35×6 (CW 75)0.40, 0.45, 0.50, 0.6012
Wall C stud (drywall)CW 74×42×6 (CW 75)0.45, 0.50, 0.6012
Wall C stud (drywall)CW 74×47×6 (CW 75)0.45, 0.50, 0.60, 0.80, 0.90, 1.00⁦8–12⁩
Wall C stud (drywall)CW 99×35×6 (CW 100)0.45, 0.50, 0.608
Wall C stud (drywall)CW 99×42×6 (CW 100)0.45, 0.50, 0.608
Wall C stud (drywall)CW 99×47×6 (CW 100)0.45, 0.50, 0.60, 0.80, 0.90, 1.008
Wall U track (drywall)UW 50×240.35, 0.4012
Wall U track (drywall)UW 50×300.40, 0.45, 0.50, 0.6012
Wall U track (drywall)UW 50×380.40, 0.45, 0.50, 0.60, 0.7012
Wall U track (drywall)UW 75×240.35, 0.4012
Wall U track (drywall)UW 75×300.40, 0.45, 0.50, 0.6012
Wall U track (drywall)UW 75×380.40, 0.45, 0.5012
Wall U track (drywall)UW 100×280.40, 0.45, 0.50, 0.6012
Wall U track (drywall)UW 100×380.40, 0.45, 0.50, 0.60, 0.708

Weight in kg/m = centre-line length L (mm) × thickness t (mm) × 7.85 × 10⁻³, with L = (web − t) + 2 (flange − t/2) for the plain U sections (UD, UW) and L = (web − t) + 2 (flange − t) + 2 (lip − t/2) for the C sections with 6 mm lips (CD, CW). Galvanising and any stiffening ribs are not included, so these are nominal values. Weight per bundle = kg/m × 3.0 m × pieces per bundle. Ix and Iy are gross section properties from the same nominal dimensions (corner radii and stiffening ribs ignored; not for structural design, effective properties to EN 1993-1-3 on request).

Another length, or a size that is not listed: describe it in the note field of the request list.

Not on the list?

A different size, grade or a roll of strap: describe it in the note field of the request list.